raz design incmedicalHigh PriorityActive

Raz-AT (Attendant Tilt) Mobile Shower Commode Chair, Catalog Number Z300 UDI-DI code: (01)00628758003007 Raz-ART (Attendant Rotational Tilt) Mobile Shower Commode Chair, Catalog Number Z333 UDI-DI code: (01)00628758003335 Raz-AT600 (Bariatric Tilt) Mobile Shower Commode Chair, Catalog Number Z360 UDI-DI code: (01)00628758003601 Raz-SP (Self Propel) Mobile Shower Commode Chair, Catalog Number Z200 UDI-DI code: (01)00628758001003 Raz-AP (Attendant Propel) Mobile Shower Commode Chair, Catalog Number Z100 UDI-DI code: (01)00628758001003 The Raz Mobile Shower Commode Chair is intended to be used by people with mobility impairments, who may have difficulty in standing or keeping their balance while completing activities such as showering, toileting, or personal hygiene.

Raz-AT (Attendant Tilt) Mobile Shower Commode Chair, Catalog Number Z300 UDI-DI code: (01)00628758003007 Raz-ART (Attendant Rotational Tilt) Mobile Shower Commode Chair, Catalog Number Z333 UDI-DI code: (01)00628758003335 Raz-AT600 (Bariatric Tilt) Mobile Shower Commode Chair, Catalog Number Z360 UDI-DI code: (01)00628758003601 Raz-SP (Self Propel) Mobile Shower Commode Chair, Catalog Number Z200 UDI-DI code: (01)00628758001003 Raz-AP (Attendant Propel) Mobile Shower Commode Chair, Catalog Number Z100 UDI-DI code: (01)00628758001003 The Raz Mobile Shower Commode Chair is intended to be used by people with mobility impairments, who may have difficulty in standing or keeping their balance while completing activities such as showering, toileting, or personal hygiene. was recalled because due to a modification by a vendor and may be reinstalled without properly engaging the outside rear seat brackets that are used to keep the seat in place.. If you have this product, stop using it until you verify your lot or model details.

By RecallRadar Editorial Team

Sourced from FDA. Last verified April 6, 2026.

On this page

Free checker

Check if you qualify

See whether your device may qualify for a free repair or replacement program before you spend money.

Check if you qualify

Key facts

Date announced
March 18, 2026
Source agency
FDA

This recall involves safety concerns. Take action promptly.

Plain-English Summary

Raz-AT (Attendant Tilt) Mobile Shower Commode Chair, Catalog Number Z300 UDI-DI code: (01)00628758003007 Raz-ART (Attendant Rotational Tilt) Mobile Shower Commode Chair, Catalog Number Z333 UDI-DI code: (01)00628758003335 Raz-AT600 (Bariatric Tilt) Mobile Shower Commode Chair, Catalog Number Z360 UDI-DI code: (01)00628758003601 Raz-SP (Self Propel) Mobile Shower Commode Chair, Catalog Number Z200 UDI-DI code: (01)00628758001003 Raz-AP (Attendant Propel) Mobile Shower Commode Chair, Catalog Number Z100 UDI-DI code: (01)00628758001003 The Raz Mobile Shower Commode Chair is intended to be used by people with mobility impairments, who may have difficulty in standing or keeping their balance while completing activities such as showering, toileting, or personal hygiene. was recalled because due to a modification by a vendor and may be reinstalled without properly engaging the outside rear seat brackets that are used to keep the seat in place.. If you have this product, stop using it until you verify your lot or model details.

Is This Recall Still Active?

Status: Yes - Active

This recall is currently active. If your device matches the affected models, follow the official instructions as soon as possible.

What's Being Recalled

Quoted source excerpt from the official notice.

Due to a modification by a vendor and may be reinstalled without properly engaging the outside rear seat brackets that are used to keep the seat in place.

Quick Info

Key facts from the official notice, kept in the article flow for easy cross-checking.

Brand
Raz design inc
Category
medical
Source agency
FDA
Announced
March 18, 2026
Country
US
Status
Active

Who's Affected

Specific models and identifiers listed in the source notice:

Model #1

Raz-AT (Attendant Tilt) Mobile Shower Commode Chair Catalog Number Z300 Seat Catalog Numbers: ZVFIFAR17 ZVFIFAR20 ZCSEAT (FAR) UDI-DI code: (01)00628758003007 Serial Numbers: RAT218789 RAT116906 RAT200337 RAT208010 RAT208987 RAT210426 RAT211344 RAT211837 RAT211998 RAT212001 RAT212066 RAT212450 RAT213190 RAT213227 RAT214334 RAT217987 RAT218213 RAT218552 RAT218570 RAT218612 RAT219142 RAT220066 RAT222210 RAT223140 RAT224902 RAT206923 RAT217768 RAT221724 RAT213036 RAT218862 RAT221044 RAT216437 RAT217073 RAT218555 RAT218557 RAT219817 RAT121348 RAT216055 RAT217379 RAT220648 RAT124264 RAT200864 Raz-ART (Attendant Rotational Tilt) Mobile Shower Commode Chair Catalog Number Z333 Seat Catalog Numbers: ZVFIFAR17 ZVFIFAR20 ZCSEAT (FAR) UDI-DI code: (01)00628758003335 Serial Numbers: ART219556 ART222544 ART211605 ART223825 ART212722 ART212675 Raz-AT600 (Bariatric Tilt) Mobile Shower Commode Chair Catalog Number Z360 Seat Catalog Numbers: ZCSEATHD (FAR) UDI-DI code: (01)00628758003601 Serial Numbers: BAT216618 BAT204112 Raz-SP (Self Propel) Mobile Shower Commode Chair Catalog Number Z200 Seat Catalog Numbers: ZVFIFAR17 ZVFIFAR20 ZCSEAT (FAR) UDI-DI code: (01)00628758001003 Serial Numbers: RAS210872 RAS214903 RAS217818 RAS220760 RAS209166 RAS218239 RAS107030 RAS214470 Raz-AP (Attendant Propel) Mobile Shower Commode Chair Catalog Number Z100 Seat Catalog Numbers: ZVFIFAR17 ZVFIFAR 20 ZCSEAT (FAR) UDI-DI code: (01)00628758001003 Serial Numbers: RAS217210 RAS224711 RAS214364 FAR Seat (Demo) Catalog Numbers: ZVFI17FAR-A ZCSEAT-A UDI-DI code: N/A Serial Numbers: N/A

Technical model codes are manufacturer identifiers. Match both the product name and model code from your device settings, label, or packaging.

What You Should Do

Follow the remedy path from the official notice using the exact model and serial details above.

  1. 1Stop using the affected product until you verify whether your item is impacted.
  2. 2Check the official recall notice and match your model, lot, or serial details.
  3. 3Follow the official instructions for repair, replacement, refund, or disposal.
Open Official Recall Notice

Source & Verification

This page summarizes the official notice and keeps key facts easy to verify.

Official source
FDA
Announced by source
March 18, 2026
Last reviewed by RecallRadar
April 6, 2026

Frequently Asked Questions

Am I affected by this recall?

Check the affected models section on this page. The official notice currently lists Raz-AT (Attendant Tilt) Mobile Shower Commode Chair Catalog Number Z300 Seat Catalog Numbers: ZVFIFAR17 ZVFIFAR20 ZCSEAT (FAR) UDI-DI code: (01)00628758003007 Serial Numbers: RAT218789 RAT116906 RAT200337 RAT208010 RAT208987 RAT210426 RAT211344 RAT211837 RAT211998 RAT212001 RAT212066 RAT212450 RAT213190 RAT213227 RAT214334 RAT217987 RAT218213 RAT218552 RAT218570 RAT218612 RAT219142 RAT220066 RAT222210 RAT223140 RAT224902 RAT206923 RAT217768 RAT221724 RAT213036 RAT218862 RAT221044 RAT216437 RAT217073 RAT218555 RAT218557 RAT219817 RAT121348 RAT216055 RAT217379 RAT220648 RAT124264 RAT200864 Raz-ART (Attendant Rotational Tilt) Mobile Shower Commode Chair Catalog Number Z333 Seat Catalog Numbers: ZVFIFAR17 ZVFIFAR20 ZCSEAT (FAR) UDI-DI code: (01)00628758003335 Serial Numbers: ART219556 ART222544 ART211605 ART223825 ART212722 ART212675 Raz-AT600 (Bariatric Tilt) Mobile Shower Commode Chair Catalog Number Z360 Seat Catalog Numbers: ZCSEATHD (FAR) UDI-DI code: (01)00628758003601 Serial Numbers: BAT216618 BAT204112 Raz-SP (Self Propel) Mobile Shower Commode Chair Catalog Number Z200 Seat Catalog Numbers: ZVFIFAR17 ZVFIFAR20 ZCSEAT (FAR) UDI-DI code: (01)00628758001003 Serial Numbers: RAS210872 RAS214903 RAS217818 RAS220760 RAS209166 RAS218239 RAS107030 RAS214470 Raz-AP (Attendant Propel) Mobile Shower Commode Chair Catalog Number Z100 Seat Catalog Numbers: ZVFIFAR17 ZVFIFAR 20 ZCSEAT (FAR) UDI-DI code: (01)00628758001003 Serial Numbers: RAS217210 RAS224711 RAS214364 FAR Seat (Demo) Catalog Numbers: ZVFI17FAR-A ZCSEAT-A UDI-DI code: N/A Serial Numbers: N/A.

What is the remedy for this recall?

Follow the official instructions for repair, replacement, refund, or disposal on the raz design inc recall page.

Where can I verify recall details?

Use the official source link in this page to confirm dates, eligibility, and next steps: https://api.fda.gov/device/enforcement.json?search=recall_number:Z-1498-2026&limit=1

Keep browsing with these internal hubs: raz design inc recall hub and Medical recall hub.

Official Resources

Use these primary sources for final eligibility and claim instructions.

View official notice from FDA

See an inaccuracy?

Help us improve the accuracy of this recall information.

500 characters remaining

Related Recalls

Boston scientific corporation
High PriorityActive

Rapid Refill Continuous Injection System, UPN M00566001

Devices contain recalled Medline Namic Angiographic Control Syringe with Rotating Adaptor. There is a risk of syringe loosening or disconnecting from the manifold, resulting in loose connection or complete disconnection. May lead to difficulty connecting syringe, inability to aspirate or inject properly, fluid leakage, or separation of the syringe from the system, potentially requiring device exchange and prolonging the procedure.

Jul 22, 2026

Papablic inc
High PriorityActive

Papablic Replacement Brush Heads. Model Number: Papablic18B

Potential for brush heads to break.

Jul 22, 2026

Orthofix u.s. llc
High PriorityActive

Orthofix MINIRAIL, STANDARD LENGTHENER Model/Catalog Number: M101, Unilateral orthopedic/trauma external fixation device

Unilateral external fixation devices may be incorrectly labeled. Minirail M101 was labeled as M103, Minirail M103 was labeled as M101, and Minirail M122 was labeled as M111

Jul 22, 2026

Papablic inc
High PriorityActive

Papablic Replacement Brush Heads. Model Number: PAPA317AA.

Potential for brush heads to break.

Jul 22, 2026

Abiomed, inc.
High PriorityActive

ABIOMED Impella CP Set, Pump Set Code 0048-0003, containing BIOMED Impella Introducer, 14 Fr, 13 cm & 25 cm, Product Code 0052-3046. heart pump and accessories

A potential for introducer sheath leakage from under the sheath cap and along the hub score lines, identified in 14Fr and 23Fr Introducers. These manufacturing issues are not visually detectable by the user, and 14Fr or 23Fr Introducers are provided in every pump set.

Jul 22, 2026